Crimp and Cleave Specifications

Parameter Value
Fiber Sizes 75, 125, and 140 microns
Diameter 0.148 inches
Finished Length 3.250 inches, including crimp sleeves
Materials Stainless steel, glass, plastic, RTV, and silicone oil. (Heat shrink tubing optional) All are mold resistant.
Termination Procedure Hand crimp; no messy chemicals
Operating temperature -55° C to +150° C
Coating Sizes 250, 500, 600, 900 microns, 1.2 mm
Cable Sizes 1.6, 1.8, 2.0, 2.5 mm
Typical splice loss ≤ 0.5 dB
Back Reflection Typically < -50 dB
Fiber Pull Strength 11.8 lbs on coated fiber; 50 to 85 lbs for Kevlar reinforced cable
Thermal shock delta 0.14 dB (-55° C to +125° C, 5 cycles)